Search

Call 1300 799 969 | Contact Us

Acoustic Attenuators and Silencers

Acoustic Attenuators and Silencers

Flexshield Sonic Acoustic Attenuators for Superior Noise Control Solution

A Sonic Acoustic Attenuator is used to reduce noise in various industrial environments. A Sonic Acoustic Attenuator may be used in the following scenarios:

  • Reduce noise from machinery and equipment
  • Comply with OHS regulations
  • Mitigate noise from cooling systems and services in data centres
  • Control sound levels in tunnels and stations
  • Protect nearby residential areas and sensitive environments from excessive noise

Sonic Acoustic Attenuator Performance

  • Noise reduction capabilities from 10 dB(A) to 50 dB(A)
  • Minimal pressure loss
  • High-temperature applications – suitable for high-temperature environments where traditional materials might degrade
  • Easy integration into duct systems
  • Podded or unpodded options.

Sonic Acoustic Attenuator Construction

These attenuators are designed to withstand the demanding Australian environment. They reduce noise along air paths without hindering airflow and maintain minimal pressure drop.

Our Sonic Acoustic Attenuators are built to be durable and made from materials such as galvanised steel or aluminium. They feature internal linings and acoustic materials like fibreglass or foam to improve noise reduction.

Cylindrical silencers are important for airflow through circular pipes. Standard silencers allow air to flow straight through, reducing average noise with minimal pressure drop. Podded cylindrical silencers offer greater noise reduction but may increase pressure drop.

The silencers’ effectiveness depends on their degree of closure and length.

Circular silencers are suitable for suction pipelines, while rectangular acoustic attenuators are ideal for large-scale HVAC systems with rectangular air channels for optimal performance.

Podded Cylindrical Silencer

A podded cylindrical silencer is a noise control device primarily used in HVAC systems to reduce airflow-generated noise. The “podded” and “cylindrical” aspects refer to its shape and design characteristics.

Cylindrical Shape: Efficient airflow and easy integration into duct systems.

Podded Design: An internal pod enhances noise reduction by disrupting sound waves and increasing reflection and absorption.

Sound Attenuation: Absorbs sound waves and reduces their transmission through ductwork, using sound-absorbing materials and a design that creates multiple pathways for sound waves, causing them to lose energy.

Unpodded Sonic Acoustic Attenuator

An unpodded acoustic attenuator, or unlined or unlagged attenuator, reduces noise levels in ducted air systems without using traditional sound-absorbing materials like fibreglass or foam linings. Lack of internal padding uses alternative methods such as airflow direction changes, turbulence, or specially designed internal geometries to attenuate noise. These are typically constructed from metals like galvanised steel or aluminium, with perforated metal surfaces or complex internal pathways. The airflow design creates paths that reduce noise through reflection, diffusion, and interferences using baffles, labyrinthine paths, or other structures.

Sonic Acoustic Attenuator Accessories

  • Acoustically and thermally rated expansion joints are custom-manufactured to fit attenuator cases.
  • Exhaust stacks are designed to withstand environmental loads.
  • Fabrication in compliance with AS4100 and AS1554

Sonic Acoustic Attenuators Testing and Compliance

The acoustic performance (insertion loss) has been rigorously tested according to ISO7235:2023 standards. The tapered splitter designs ensure minimal pressure drops.

A pressure drop is the difference in total pressure between two points in a fluid-carrying network. This drop or loss occurs when a liquid material enters one end of a piping system and exits the other.

How to Specify Sonic Acoustic Attenuators

Where allocated, supply Flexshield Sonic Acoustic Attenuators. They should be painted with Dulux’ grey nurse’ in colour.

The Sonic Acoustic Attenuator should be designed to provide acoustic noise reduction at specific frequency bands as follows:

NR – Noir Reduction/IL – Insert Loss (dB) 125, 250, 500, 1K, 2K, 4K.

Phone: 1300 799 969

Email: sales@flexshield.com.au

Fabricated and installed to manufacturer specifications. Qty and sizes found on drawing numbers: _________

At Flexshield, we pride ourselves on providing high-quality noise control solutions to meet our customers’ needs. Contact us today to learn more about our Sonic Acoustic Attenuators and how we can help with your noise control requirements.

Download our product brochures and resources

"(Required)" indicates required fields

This field is for validation purposes and should be left unchanged.

Download will be available on the next screen

Thanks for getting in contact. Please download as many resources as you wish here.

Note: Flexshield provides industrial acoustic solutions.
For commercial click here. For small or domestic enquiries click here.

We are proud to work with to some of Australia’s greatest brands