Search
Close this search box.

Call 1300 799 969 | Contact Us

Test Results – SonicClear 3mm strip curtain 100mm overlap attenuation

SonicClear 3mm strip curtain attenuation test report

Download the RMIT University laboratory test report for the Flexshield SonicClear 3mm strip curtain to review airborne transmission loss and Weighted Sound Reduction Index data for a 100mm overlap configuration.

What you’ll find in the report

  • Airborne transmission loss results from 100Hz to 5000Hz
  • A Weighted Sound Reduction Index of Rw 19
  • Spectrum adaptation terms of C -1dB and Ctr -2dB
  • Test data for 300mm wide, 3mm thick SonicClear panels with 100mm overlaps
  • One-third octave band transmission loss data and the Rw reference curve
  • Testing completed in accordance with AS 1191-2002
  • Rw determined in accordance with AS/NZS ISO 717.1-2004
  • Testing completed by RMIT University’s NATA-accredited Applied Acoustics Laboratory

The report documents laboratory testing of a 3mm SonicClear strip curtain configuration using 300mm wide panels with 100mm overlaps, mounted on a 500 Series Acoustic Track. The tested panels had a nominal surface density of 3.66kg/m².

The tested curtain achieved Rw (C;Ctr) = 19(-1;-2), with measured transmission loss results provided across frequencies from 100Hz to 5000Hz.

Cover image of the SonicClear test results.