Safe welding fume extraction helps remove airborne welding fumes from the breathing zone, supporting healthier workshop environments for students and teachers.
Designed to integrate with individual welding bays or complete workshop layouts, extraction equipment helps maintain clear work areas while supporting practical teaching and safe workshop practices.
Safe welding fume extraction can be supplied as a standalone product or incorporated into a Complete acoustic welding bay, making it suitable for new Trade Training Centres, workshop upgrades and staged refurbishments.
Safe welding fume extraction Components
Every Trade Training Centre is different. Safe welding fume extraction is configured around the workshop layout, allowing installations from a single welding bay through to complete Trade Training Centre workshops.
Safe welding fume extraction is supplied with supporting technical documentation to assist with specification, procurement and project delivery.
Documentation is available for relevant recognised AS/NZS standards where applicable, ISO 9001 Quality Management, ISO 14001 Environmental Management, AS4801 Occupational Health and Safety, together with manufacturer performance information and installation documentation.
Copy and amend the schedule below to suit your project requirements.
| Item | Requirement |
| Project name | |
| Education facility | |
| Number of welding bays | |
| Extraction arms | Qty ____ |
| Fan / Filtration Unit | Yes / No |
| Ducting requirements | ________________ |
| Installation | Supply Only / Supply & Install |
| Standalone product or Complete acoustic welding bay | Standalone / Complete Bay |
Need assistance? Flexshield can assist with workshop planning, extraction selection and specification documentation for education projects.
Supporting technical information is available to assist architects, specifiers, builders and education providers during specification and project delivery.
| Component | Testing Standard | Compliance Requirements | Performance Criteria |
| Extraction arms | AS/NZS 4114.1 | Capture at source Positioning |
Capture efficiency Ease of adjustment |
| Extraction unit | AS 4289 | Airflow Filtration |
Filter performance Workshop suitability |
| Support system | AS/NZS 1554 | Structural integrity | Durability Secure installation |
Flexshield operates certified management systems including ISO 9001, ISO 14001 and AS4801. Detailed product information and supporting technical documentation are available on request.
Safe welding fume extraction helps remove airborne welding fumes from the breathing zone, supporting healthier workshop environments for students and teachers.
Designed to integrate with individual welding bays or complete workshop layouts, extraction equipment helps maintain clear work areas while supporting practical teaching and safe workshop practices.
Safe welding fume extraction can be supplied as a standalone product or incorporated into a Complete acoustic welding bay, making it suitable for new Trade Training Centres, workshop upgrades and staged refurbishments.
Safe welding fume extraction Components
Every Trade Training Centre is different. Safe welding fume extraction is configured around the workshop layout, allowing installations from a single welding bay through to complete Trade Training Centre workshops.
Safe welding fume extraction is supplied with supporting technical documentation to assist with specification, procurement and project delivery.
Documentation is available for relevant recognised AS/NZS standards where applicable, ISO 9001 Quality Management, ISO 14001 Environmental Management, AS4801 Occupational Health and Safety, together with manufacturer performance information and installation documentation.
Copy and amend the schedule below to suit your project requirements.
| Item | Requirement |
| Project name | |
| Education facility | |
| Number of welding bays | |
| Extraction arms | Qty ____ |
| Fan / Filtration Unit | Yes / No |
| Ducting requirements | ________________ |
| Installation | Supply Only / Supply & Install |
| Standalone product or Complete acoustic welding bay | Standalone / Complete Bay |
Need assistance? Flexshield can assist with workshop planning, extraction selection and specification documentation for education projects.
Supporting technical information is available to assist architects, specifiers, builders and education providers during specification and project delivery.
| Component | Testing Standard | Compliance Requirements | Performance Criteria |
| Extraction arms | AS/NZS 4114.1 | Capture at source Positioning |
Capture efficiency Ease of adjustment |
| Extraction unit | AS 4289 | Airflow Filtration |
Filter performance Workshop suitability |
| Support system | AS/NZS 1554 | Structural integrity | Durability Secure installation |
Flexshield operates certified management systems including ISO 9001, ISO 14001 and AS4801. Detailed product information and supporting technical documentation are available on request.
We are proud to work with some of Australia’s greatest brands
Safe welding fume extraction uses source capture equipment to help remove airborne welding fumes from the breathing zone. Extraction arms can be positioned near welding activities to capture fumes at their source, supporting healthier workshop environments for students and teachers. The appropriate equipment and configuration depend on the welding activities and workshop requirements.
Safe welding fume extraction can incorporate source capture extraction arms, extraction fans and ducting, with high-efficiency filtration where required. Flexible arm positioning and wall-mounted or workshop-mounted configurations allow equipment to be planned around student workstations. Flexshield can assist with selecting components suited to the project.
Yes. Safe welding fume extraction can be supplied for new workshops, upgrades and staged refurbishments. It can be configured for individual welding bays or complete workshop layouts, either as a standalone installation or incorporated into a Complete acoustic welding bay. The arrangement depends on the available space, existing infrastructure and project requirements.
Extraction arms should be positioned to support capture at the source while allowing students to carry out welding activities and teachers to supervise the work area. The number of workstations, arm reach, adjustment requirements and workshop layout should be considered during planning. Flexshield can assist with extraction selection and positioning requirements.
Project teams should identify the number of welding bays, required extraction arms, fan or filtration requirements and any ducting needs. The specification schedule also allows you to indicate whether the equipment is required as a standalone installation or as part of a Complete acoustic welding bay, along with supply-only or supply and installation preferences. Flexshield can provide manufacturer performance information, installation documentation and supporting technical information to assist with specification and procurement.