| Weight | NRC Rating | Rw Rating (dB) | Key Application |
|---|---|---|---|
| 6.5 kg | 0.85 | 27 | Light to moderate noise control; general industrial machinery and equipment enclosures |
| 8.5 kg | 0.90 | 30 | Standard noise control: construction sites, manufacturing facilities, and rooftop plant equipment |
| Component | Description |
|---|---|
| Outer Material | Heavy-duty reinforced vinyl for durability and weather resistance |
| Sound Barrier Core | Loaded vinyl sound barrier for superior noise transmission loss |
| Absorption Layer | Acoustic foam or polyester absorption layer for enhanced sound absorption |
| Material Safety | Non-toxic materials are safe to handle in accordance with Safety Data Sheet requirements |
| Environmental | No Volatile Organic Compounds (VOCs) or ozone-depleting substances are used in the manufacture |
| Specification | Details |
|---|---|
| Panel Width | 1250mm |
| Panel Height | 2000mm |
| Finished Product Format | Pre-fabricated curtain panels ready for installation |
| Customisation | Can be customised to suit specific project requirements |
| Portability | Lightweight panels designed for easy transport and repositioning between sites |
| Treatment Type | Specification |
|---|---|
| UV Resistance | UV-resistant outer material for outdoor durability |
| Fire Resistance | Fire-resistant facing tested to AWTA standards |
| Burn Properties | Self-extinguishing properties meet FMVSS-302 automotive burn rate standards |
| Weather Protection | Weatherproof coating protects against moisture and environmental exposure |
| Colour Options | Blue, olive, and other colours available on request |
| Property | Specification |
|---|---|
| Base Fabric | High tensile strength tarpaulin base fabric withstands harsh weather and wind conditions |
| Tear Resistance | Tear-resistant construction tolerates high wind conditions and mechanical stress |
| Span Capability | Ability to suspend in lengths exceeding 10 metres without sagging |
| Fastening Options | Hook and loop fasteners, eyelets, grommets, or custom fastening systems |
| Flexibility | Flexible design allows draping over fencing, scaffolding, and temporary structures |
| Operating Temperature | -40°C to 100°C (intermittent up to 120°C) |
| Chemical Resistance | Resistant to most chemicals, solvents, and petrol for versatile industrial use |
| Specification | Details |
|---|---|
| Testing Standard | Tested according to AS ISO 354 |
| Testing Facility | RMIT University’s Applied Physics Discipline reverberation room |
| Rating Standard | Sound absorption rating according to AS ISO 11654-1997 |
| NRC Achievement | Achieves up to NRC 0.93 across key frequencies |
| Accreditation | NATA-accredited testing |
| Specification | Details |
|---|---|
| Testing Standard | Tested in accordance with AS 1191-2002 |
| Rw Determination | Rw determined to AS/NZS ISO 717.1-2004 |
| 6.5 kg Curtain Performance | Achieves Rw 27 dB sound reduction |
| 8.5 kg Curtain Performance | Achieves Rw 30 dB sound reduction |
| Laboratory Verification | Laboratory-verified attenuation results available for all weights |
| Specification | Details |
|---|---|
| Outer Material Test | FMVSS-302 – Self-extinguishing burn rate (Automotive burn rate standard) |
| Outer Material Test | UL94 – After flame time <2sec (HBF – Horizontal burn test compliant) |
| Inner Material Test | NCC C1.10-4 – 20mins-100kw Fire (No flash point reached – Highest possible achievement) |
| Test Provider | Independently tested by AWTA Limited |
| Documentation | Full fire test results available upon request |
| Specification | Details |
|---|---|
| Wind Resistance | Tested for wind load performance across various support configurations |
| Durability Assessment | Verified for long-term performance in harsh environmental conditions |
| Material Strength | High tensile strength tarpaulin base fabric withstands mechanical stress |
| Document Type | Details |
|---|---|
| NATA Attenuation Test Results | Full sound transmission loss data for 6.5 kg and 8.5 kg curtains |
| Absorption Coefficient Reports | Detailed frequency-specific absorption data |
| Sound Absorption Coefficients | Complete NRC ratings across all frequency bands |
| Fire Test Certificates | AWTA Limited test results for flammability compliance |
| Complete Test Certificates | Available upon request for: Sonic Acoustic Curtain – 6.5 kg (Rw 27), 8.5 kg (Rw 30) |
| Specification | Details |
|---|---|
| Manufacturing Standards | Manufactured to Australian Standards |
| Quality Control | Regular quality control testing throughout production |
| Documentation | Full documentation and certification are available |
| Laboratory Accreditation | NATA-accredited laboratory testing ensures reliable performance |
| Compliance Verification | All products are tested and verified to meet the stated acoustic performance |
Sonic Acoustic Curtains are tested by RMIT University in accordance with AS/NZS ISO717.1-2004.
| Frequency (Hz) | 6.5 kg dB | 8.5 kg dB |
|---|---|---|
| 100 | 13.3 | 14.0 |
| 125 | 15.2 | 17.3 |
| 150 | 14.4 | 17.1 |
| 200 | 16.1 | 17.8 |
| 250 | 17.4 | 21.1 |
| 315 | 17.7 | 21.8 |
| 400 | 19.9 | 23.4 |
| 500 | 21.3 | 24.9 |
| 630 | 23.3 | 26.9 |
| 800 | 25.9 | 29.5 |
| 1000 | 28.6 | 32.0 |
| 1250 | 31.0 | 34.3 |
| 1600 | 33.4 | 36.9 |
| 2000 | 35.7 | 39.5 |
| 2500 | 38.1 | 41.0 |
| 3150 | 40.4 | 43.4 |
| 4000 | 42.5 | 45.4 |
| 5000 | 44.3 | 47.5 |
Sonic Acoustic Curtains are tested by RMIT University in accordance with AS/NZS ISO717.1-2004.
| Frequency (Hz) | NRC |
|---|---|
| 100 | 0.29 |
| 125 | 0.26 |
| 160 | 0.29 |
| 200 | 0.33 |
| 250 | 0.49 |
| 315 | 0.64 |
| 400 | 0.74 |
| 500 | 0.79 |
| 630 | 0.80 |
| 800 | 0.85 |
| 1000 | 0.85 |
| 1250 | 0.86 |
| 1600 | 0.89 |
| 2000 | 0.85 |
| 2500 | 0.87 |
| 3150 | 0.86 |
| 4000 | 0.90 |
| 5000 | 0.93 |
Sonic Acoustic Curtains are tested by AWTA Limited and are NATA-accredited.
| Material | Test Method | Index | Results | Description |
|---|---|---|---|---|
| Outer Material | FMVSS-302 | Burn Rate – mm/min | Self-Extinguishing | Automotive burn rate |
| Outer Material | UL94 | After flame time <2sec | HBF | Horizontal burn test. Complies |
| Inner Material | NCC C1.10-4 | 20mins-100kw Fire | No flash point reached | Highest possible achievement |
Sonic Acoustic Curtains are available in standard sizes or custom-made to suit your requirements.
| Weight | NRC Rating | Rw Rating (dB) | Key Application |
|---|---|---|---|
| 6.5 kg | 0.85 | 27 | Light to moderate noise control; general industrial machinery and equipment enclosures |
| 8.5 kg | 0.90 | 30 | Standard noise control: construction sites, manufacturing facilities, and rooftop plant equipment |
| Component | Description |
|---|---|
| Outer Material | Heavy-duty reinforced vinyl for durability and weather resistance |
| Sound Barrier Core | Loaded vinyl sound barrier for superior noise transmission loss |
| Absorption Layer | Acoustic foam or polyester absorption layer for enhanced sound absorption |
| Material Safety | Non-toxic materials are safe to handle in accordance with Safety Data Sheet requirements |
| Environmental | No Volatile Organic Compounds (VOCs) or ozone-depleting substances are used in the manufacture |
| Specification | Details |
|---|---|
| Panel Width | 1250mm |
| Panel Height | 2000mm |
| Finished Product Format | Pre-fabricated curtain panels ready for installation |
| Customisation | Can be customised to suit specific project requirements |
| Portability | Lightweight panels designed for easy transport and repositioning between sites |
| Treatment Type | Specification |
|---|---|
| UV Resistance | UV-resistant outer material for outdoor durability |
| Fire Resistance | Fire-resistant facing tested to AWTA standards |
| Burn Properties | Self-extinguishing properties meet FMVSS-302 automotive burn rate standards |
| Weather Protection | Weatherproof coating protects against moisture and environmental exposure |
| Colour Options | Blue, olive, and other colours available on request |
| Property | Specification |
|---|---|
| Base Fabric | High tensile strength tarpaulin base fabric withstands harsh weather and wind conditions |
| Tear Resistance | Tear-resistant construction tolerates high wind conditions and mechanical stress |
| Span Capability | Ability to suspend in lengths exceeding 10 metres without sagging |
| Fastening Options | Hook and loop fasteners, eyelets, grommets, or custom fastening systems |
| Flexibility | Flexible design allows draping over fencing, scaffolding, and temporary structures |
| Operating Temperature | -40°C to 100°C (intermittent up to 120°C) |
| Chemical Resistance | Resistant to most chemicals, solvents, and petrol for versatile industrial use |
| Specification | Details |
|---|---|
| Testing Standard | Tested according to AS ISO 354 |
| Testing Facility | RMIT University’s Applied Physics Discipline reverberation room |
| Rating Standard | Sound absorption rating according to AS ISO 11654-1997 |
| NRC Achievement | Achieves up to NRC 0.93 across key frequencies |
| Accreditation | NATA-accredited testing |
| Specification | Details |
|---|---|
| Testing Standard | Tested in accordance with AS 1191-2002 |
| Rw Determination | Rw determined to AS/NZS ISO 717.1-2004 |
| 6.5 kg Curtain Performance | Achieves Rw 27 dB sound reduction |
| 8.5 kg Curtain Performance | Achieves Rw 30 dB sound reduction |
| Laboratory Verification | Laboratory-verified attenuation results available for all weights |
| Specification | Details |
|---|---|
| Outer Material Test | FMVSS-302 – Self-extinguishing burn rate (Automotive burn rate standard) |
| Outer Material Test | UL94 – After flame time <2sec (HBF – Horizontal burn test compliant) |
| Inner Material Test | NCC C1.10-4 – 20mins-100kw Fire (No flash point reached – Highest possible achievement) |
| Test Provider | Independently tested by AWTA Limited |
| Documentation | Full fire test results available upon request |
| Specification | Details |
|---|---|
| Wind Resistance | Tested for wind load performance across various support configurations |
| Durability Assessment | Verified for long-term performance in harsh environmental conditions |
| Material Strength | High tensile strength tarpaulin base fabric withstands mechanical stress |
| Document Type | Details |
|---|---|
| NATA Attenuation Test Results | Full sound transmission loss data for 6.5 kg and 8.5 kg curtains |
| Absorption Coefficient Reports | Detailed frequency-specific absorption data |
| Sound Absorption Coefficients | Complete NRC ratings across all frequency bands |
| Fire Test Certificates | AWTA Limited test results for flammability compliance |
| Complete Test Certificates | Available upon request for: Sonic Acoustic Curtain – 6.5 kg (Rw 27), 8.5 kg (Rw 30) |
| Specification | Details |
|---|---|
| Manufacturing Standards | Manufactured to Australian Standards |
| Quality Control | Regular quality control testing throughout production |
| Documentation | Full documentation and certification are available |
| Laboratory Accreditation | NATA-accredited laboratory testing ensures reliable performance |
| Compliance Verification | All products are tested and verified to meet the stated acoustic performance |
Sonic Acoustic Curtains are tested by RMIT University in accordance with AS/NZS ISO717.1-2004.
| Frequency (Hz) | 6.5 kg dB | 8.5 kg dB |
|---|---|---|
| 100 | 13.3 | 14.0 |
| 125 | 15.2 | 17.3 |
| 150 | 14.4 | 17.1 |
| 200 | 16.1 | 17.8 |
| 250 | 17.4 | 21.1 |
| 315 | 17.7 | 21.8 |
| 400 | 19.9 | 23.4 |
| 500 | 21.3 | 24.9 |
| 630 | 23.3 | 26.9 |
| 800 | 25.9 | 29.5 |
| 1000 | 28.6 | 32.0 |
| 1250 | 31.0 | 34.3 |
| 1600 | 33.4 | 36.9 |
| 2000 | 35.7 | 39.5 |
| 2500 | 38.1 | 41.0 |
| 3150 | 40.4 | 43.4 |
| 4000 | 42.5 | 45.4 |
| 5000 | 44.3 | 47.5 |
Sonic Acoustic Curtains are tested by RMIT University in accordance with AS/NZS ISO717.1-2004.
| Frequency (Hz) | NRC |
|---|---|
| 100 | 0.29 |
| 125 | 0.26 |
| 160 | 0.29 |
| 200 | 0.33 |
| 250 | 0.49 |
| 315 | 0.64 |
| 400 | 0.74 |
| 500 | 0.79 |
| 630 | 0.80 |
| 800 | 0.85 |
| 1000 | 0.85 |
| 1250 | 0.86 |
| 1600 | 0.89 |
| 2000 | 0.85 |
| 2500 | 0.87 |
| 3150 | 0.86 |
| 4000 | 0.90 |
| 5000 | 0.93 |
Sonic Acoustic Curtains are tested by AWTA Limited and are NATA-accredited.
| Material | Test Method | Index | Results | Description |
|---|---|---|---|---|
| Outer Material | FMVSS-302 | Burn Rate – mm/min | Self-Extinguishing | Automotive burn rate |
| Outer Material | UL94 | After flame time <2sec | HBF | Horizontal burn test. Complies |
| Inner Material | NCC C1.10-4 | 20mins-100kw Fire | No flash point reached | Highest possible achievement |
Sonic Acoustic Curtains are available in standard sizes or custom-made to suit your requirements.
Mitchell Bentley | Contracts Administrator Field Construct
We are proud to work with some of Australia’s greatest brands
Project: Paddy Gully Road pump station Wivenhoe to Cressbrook pipeline
Industry: Utilities - Water
Location: Station Wivenhoe Dam, Qld
Client: Toowoomba Regional Council (TRC)
Project: Crusher noise control
Industry: Resources
Location: Boddington, WA
Client: Gold Mine
Yes, Sonic Acoustic Curtains are designed to comply with industry standards and noise control and safety regulations. They undergo rigorous testing to ensure they meet or exceed relevant standards, assuring their performance and reliability.
Yes, Sonic Acoustic Curtains are suitable for temporary installations, such as construction site enclosures or event spaces requiring noise control. They are lightweight, portable, and easy to install and remove as needed.
While Sonic Acoustic Curtains are durable and low-maintenance, periodic inspection and cleaning may be necessary to ensure optimal performance over time. Cleaning methods typically involve mild detergent and water, avoiding harsh chemicals that could damage the curtain materials.
Yes, Sonic Acoustic Curtains are designed to withstand outdoor conditions. They are weatherproof, UV-resistant, and often feature fire-resistant properties, making them suitable for use in both indoor and outdoor environments.
Yes, Sonic Acoustic Curtains can be customised to meet specific requirements. Customisation options include size, colour, material thickness, and additional features such as vision panels or branding/logo printing.
Yes, Sonic Acoustic Curtains are designed for ease of installation. Depending on the application, they can be mounted using various methods, such as hooks, hook and loop, or zip ties. Additionally, they come with installation instructions to ensure proper setup.
Depending on the specific application and environmental factors, Sonic Acoustic Curtains can reduce noise from 15dB to 30dB or more. However, noise reduction may vary based on the installation method, curtain thickness, and surrounding conditions.
Sonic Acoustic Curtains are versatile and can be used in various settings, including industrial facilities, construction sites, manufacturing plants, HVAC installations, and commercial spaces where noise control is essential.
Sonic Acoustic Curtains work by blocking and absorbing sound waves. They feature layers of materials that reflect, absorb, and dampen sound, thereby reducing noise levels within enclosed spaces or around designated areas.
Sonic Acoustic Curtains are innovative soundproofing solutions designed to reduce noise pollution in industrial and construction environments. They effectively combine sound barrier and noise absorption technologies to minimise noise transmission.
"(Required)" indicates required fields
Download will be available on the next screen
Note: Flexshield provides industrial acoustic solutions.
For commercial click here. For small or domestic enquiries click here.