Two products can quote the same acoustic rating and still behave differently. An engineer comparing two acoustic products may see the same Rw figure on both datasheets and reasonably assume they are interchangeable. The acoustic test reports can tell a different story.
One product may perform better at the low frequencies produced by generators, compressors or large fans. Another may be stronger through the mid and higher frequencies. The products may also have been tested to different standards, in different configurations, or with details that do not match the item being offered for the project.
That is why the useful question is not simply “what is the dB rating?” It’s whether the test data describes the product, frequency range, and installation condition that the project actually needs.
Before looking at the headline result, identify the test specimen. The report should make it possible to confirm the product name, construction, thickness, mass or other relevant configuration details. If the product being specified differs from the tested specimen, the published rating may not be directly transferable.
This matters with modular panels, curtains, doors and louvres because apparently small construction changes can alter performance. A heavier curtain is not the same test specimen as a lighter version. A single acoustic door is not the same assembly as a double door. A louvre with a different blade depth or arrangement should not inherit another model’s test result.
If the supplier cannot connect the quoted performance figure to a clearly identified test specimen, ask for the full report before relying on the number in a specification.
NATA is Australia’s national accreditation authority for laboratories and other technical organisations. For laboratory testing, accreditation to ISO/IEC 17025 provides independent recognition that the laboratory is competent to perform specific testing activities and can generate valid, reliable results.
The important word is specific. NATA accreditation does not mean every activity performed by a laboratory is automatically covered. NATA explains that endorsed reports apply to activities within the organisation’s accredited scope. When reviewing an acoustic report, check that the test itself falls within that scope rather than treating a NATA logo as a blanket product approval.
It is also worth separating accreditation from product certification. NATA accredits the competence of the organisation carrying out the test. The test report then records the performance of the specimen under the stated method and conditions.
A performance figure only becomes useful when you know how it was measured. For airborne transmission through building elements and partitions, Flexshield test documentation commonly references AS 1191 and AS/NZS ISO 717.1 for the determination of weighted airborne insulation ratings.
Other product types may need additional testing. Sonic Series acoustic louvres, for example, have acoustic performance data as well as airflow resistance and rain penetration data. A louvre cannot be selected sensibly on acoustic attenuation alone if the ventilation design also has to move a specified volume of air through the opening.
When comparing submissions, check that the products were assessed using comparable methods. A laboratory transmission-loss result, an insertion-loss figure measured in another arrangement, and a manufacturer estimate are not three versions of the same measurement.
Rw, the weighted airborne insulation rating, compresses a set of frequency-dependent transmission results into one number. That makes it useful for specifications and broad comparisons, but the single figure can hide differences that matter on industrial projects.
Flexshield’s Sonic Series acoustic louvre data illustrates the point. Two models can have the same Rw while providing different attenuation at 125 Hz. If the project noise is dominated by low-frequency plant, the frequency-band data may be more useful to the acoustic consultant than the headline Rw alone.
The same principle applies when comparing other barriers and partitions. Start with the project noise spectrum where it is available, then check whether the product data supports the required reduction at the frequencies that are driving the assessment.
Acoustic test reports may present an Rw rating with spectrum adaptation terms shown as C and Ctr. These terms adjust the single-number rating for different source spectra. They can help a consultant judge how a partition is likely to behave when the noise contains different frequency characteristics.
They should not be read as bonus points added to the Rw. An entry such as Rw (C; Ctr) = 46 (-1; -3) dB provides three related pieces of information, not a claim that the product achieves 49 dB. The project acoustic report should determine which metric is relevant to the assessment.
Generators, compressors, pumps, transformers, fans and other mechanical plant can contain strong low-frequency components. Those frequencies are often where product comparisons become more revealing.
A full transmission-loss table shows performance across frequency bands rather than hiding everything inside one weighted result. For example, Flexshield publishes frequency-specific data for Sonic Access acoustic doors and Sonic Series acoustic louvres, allowing project teams to look beyond the headline Rw.
If an acoustic consultant has specified attenuation by octave or one-third-octave band, compare the product against those bands directly. A higher overall Rw does not automatically make one product the better choice for every noise spectrum.
Laboratory testing provides a controlled way to compare the performance of a specimen. It does not mean an installed enclosure, wall, or door will reduce the measured workplace level by exactly the same number of decibels.
Installed performance is influenced by the whole construction. Gaps, penetrations, doors, ventilation openings, junctions, flanking paths and untreated sections can all change the result. The source spectrum, room reflections and measurement position also matter.
This distinction is especially important when a product page quotes an Rw rating. Rw describes the tested element under the nominated laboratory method. It is not a promise that placing that element between a machine and a worker will produce the same numerical reduction at the receiver.
Tender substitutions often arrive with a short datasheet and a headline acoustic rating. A disciplined comparison should go further.
Check that the alternative has been tested for the same function, that the tested construction matches the proposed construction and that the relevant standard is identified. Compare frequency data where the project assessment depends on particular bands. For doors and other assemblies, check the tested size and configuration. For louvres, consider airflow and weather data alongside acoustic performance.
This is also where independent testing becomes commercially useful. It gives the consultant, contractor and client a common technical reference rather than asking the project team to choose between competing marketing claims.
When reviewing an acoustic product submission, work through five questions:
If any answer is unclear, request the test report or technical data before accepting the product. The aim is not to create paperwork for its own sake. It is to make sure the specification is based on comparable evidence.
Flexshield Group manufactures industrial acoustic products in Australia and supports key product ranges with independent testing through NATA-accredited laboratories. Test documentation is available for products including Sonic System acoustic modular panels, Sonic Acoustic Curtains, Sonic Access acoustic doors and Sonic Series acoustic louvres.
For project teams comparing products, Flexshield can provide technical documentation so the nominated model, test method and relevant performance data can be checked against the project requirements. That gives engineers, consultants and contractors a clearer basis for specification than a standalone marketing figure.
We’ll make sure it’s built right from the start. Contact Flexshield on 1300 799 969 or get in touch online.
Proudly built by Flexshield Group
Designed to perform. Built to last.