Call 1300 799 969 | Contact Us
Download the engineering information for Flexshield Sonic System acoustic modular panels V50 to review allowable wind load pressures across different panel support centres.
The document provides engineering information for the Flexshield Sonic System acoustic modular panels V50, including allowable loading pressures for different panel support centres and associated installation requirements.
The listed maximum ultimate wind load pressures range from 6.0kPa at support centres up to 1.5m to 1.9kPa at 2.7m support centres, subject to the stated assembly and support conditions.